  • Bodet Harmonys 8 Zone Microphone

    Bodet Harmonys 8 Zone Microphone

    0 out of 5

    • 8-zone microphone console to broadcast live or delayed messages: keypad with capacitive keys (each key corresponds to a zone and is equipped with a green
    LED to indicate the selection of the zone).
    • 3 push-buttons to record (record with replay), to broadcast live or delayed.
    • Built-in loud-speaker to listen to the message before broadcast.
    • “Jingle” before broadcast of the message.
    • Archiving of voice messages. A filed message can be used in a step of a program.
    • Supervision: SNMP v1 and v2c.

  • Bodet Harmonys Flash Outdoor Strobe

    Bodet Harmonys Flash Outdoor Strobe

    0 out of 5

    • Controlled by the Sigma master clock by Ethernet network (IP).
    • 1 « Test » push-button (accessible by opening the controller box).
    • 2 LED give indications about the operation (LEDs visible by opening the controller box):
    – LED «~» (green) indicates that the unit is powered up.
    – LED «Ψ» (green/red) informs about the configuration of the system.
    • Duration of the control signal: 30 seconds.

  • Bodet Harmonys Indoor IP Ceiling Speaker

    Bodet Harmonys Indoor IP Ceiling Speaker

    0 out of 5

    • Sounder (for indoor) bells, melodies, voice calls and SEP* alarms.
    • 3 operating modes:
    – Broadcast of melodies stored in the product. Control by Sigma master clock (the Ethernet network) or by manual command from the control box (ex: SEP alarm).
    – Voice calls: from microphone or sent from the computer.
    – Broadcast of streaming audio and/or music from the computer.
    • The adjustment of the sound level is accomplished via the embedded web server (for all broadcasts).

  • Bodet Harmonys Indoor IP luminous flash

    Bodet Harmonys Indoor IP luminous flash

    0 out of 5

    • The luminous indoor Harmonys Flash (RGB) emits light signals in the same way as melodies are broadcast via the Harmonys audio speaker (the programming is identical to all Harmonys).
    • Controlled by the Sigma master clock via Ethernet network (IP).
    • 1 “Test” push-button.
    • 2 LEDs give indication on the operation status:
    – The green LED “~” indicates that the unit is powered up.
    – The green/red LED “Ψ” indicates that the system is being configured.
    • 4 levels of adjustable brightness.

  • Bodet Harmonys Indoor IP Wall Speaker, PoE

    Bodet Harmonys Indoor IP Wall Speaker, PoE

    0 out of 5

    • Sounder (for indoor) bells, melodies, voice calls and SEP* alarms.
    • 3 operating modes:
    – Broadcast of melodies stored in the product. Control by Sigma master clock (the Ethernet network) or by manual command from the control box (ex: SEP alarm).
    – Voice calls: from microphone or sent from the computer.
    – Broadcast of streaming audio and/or music from the computer.
    • The adjustment of the sound level is accomplished via the embedded web server (for all broadcasts).

  • Bodet Harmonys IP 4 Button Box

    Bodet Harmonys IP 4 Button Box

    0 out of 5

    • Manual control of the broadcast of a melody or of a pre-recorded message.
    • The button box controls also the messages of beginning and end of pre-recorded
    SEP* alarms.
    • “STOP” function: manual stop of all melodies being played in one or more zones.
    • 2 operating modes, “Independent” or “SIGMA”, of the button box (programmable
    via the Sigma software).
    • Identification and configuration of the product via the embedded web server.
    *SEP: Safety Emergency Procedures.

  • Bodet Harmonys IP Multizone Microphone Keyboard

    Bodet Harmonys IP Multizone Microphone Keyboard

    0 out of 5

    • Multizone microphone with zone selection by dialing a 4-digit number with capacitive keys.
    • A 4-digit number can be assigned to each group, each zone, each speaker and also to a set of zones or a set of 2 to 4 speakers.
    • Possibility to make a general call (with all speakers) and live broadcast calls.
    • Display of the name associated with the 4-digit number.
    • 3 push-buttons to record (record with replay), to broadcast live or delayed.
    • Up to 30 messages can be stored in the microphone’s internal memory.
    • Built-in loud-speaker to listen to the message before broadcast.
    • “Jingle” before broadcast of the message.
    • Archiving of voice messages.

  • Bodet Harmonys Line Paging Gateway

    Bodet Harmonys Line Paging Gateway

    0 out of 5

    Bodet Harmonys Line enables you to connect to an induction loop amplifier or a 100V audio amplifier.

    • Indoor installation, near induction equipment or 100V audio amplifier.
    • 3 Operating modes:
    – Broadcast of melodies stored in the product. Control by Sigma master clock or by manual command from the control box
    – Voice calls: from microphone or sent from the computer.
    – Broadcast of streaming audio and/or music from the computer.
    • Product settings are accomplished via the embedded web.

  • Bodet Harmonys Outdoor IP Horn Speaker

    Bodet Harmonys Outdoor IP Horn Speaker

    0 out of 5

    • Amplified sounder (for outdoor) for bells, melodies, voice calls and Lockdown alarm.
    • 3 operating modes:
    – Broadcast of melodies stored in the product. Control by Sigma master clock (the Ethernet network) or by manual command from the control box (ex: Lockdown alarm).
    – Voice calls: from microphone or sent from the computer.
    – Broadcast of streaming audio and/or music from the computer.
    • The adjustment of the sound level is accomplished via the embedded web server (for all broadcasts).

  • Bodet Harmonys Trio, PoE - All in one speaker with LED display

    Bodet Harmonys Trio, PoE – All in one speaker with LED display

    0 out of 5

    Harmonys Trio: sound, flash, and LED display. Bodet Harmonys Trio, PoE audio system can deliver a reliable time information, broadcast audio messages and send timely alerts in the event of a threat. It comprises a loudspeaker, a strobe and an LED display. Harmonys Trio is the must-have device of the Harmonys systems. Designed to cover…

  • Bodet Sigma Master Clock System

    Bodet Sigma Master Clock System

    0 out of 5
    • Automatic time setting on all clocks
    • Identical time on all clocks at the same location
    • Automatic summer/winter time changeover
    • Offers multiple output protocols for time distribution
      (Impulse, Wireless, NTP, AFNOR, etc).
    • Available for wall mounting or rack fittings
    • Programs bell systems, lighting, heating, air conditioning and access control system